Specifications
Documents

Product Overview

The B200S-LF-WH and B200S-LF-IV sounder bases are used with addressable detector heads. Refer to the appropriate manual for more information on sensors. The B200S-LF-WH/B200S-LF-IV low frequency sounder base generates a low frequency tone around 520 Hz. Studies have shown that low frequency audible devices that operate around 520 Hz are more effective in waking individuals in sleeping areas.

The sounder base is capable of producing a variety of tone patterns, including the distinctive three-pulse temporal pattern (ANSI Temporal 3) fire alarm signal now required by NFPA 72 for commercial and residential applications. The B200S-LF-WH/B200S-LF-IV offers maximum flexibility in configuration and operation to meet or exceed the requirements of UL268 and UL464 for Continuous, Temporal 3 and March time patterns. The temporal 4 pattern meets all requirements of UL268 and UL2075, as well as, private mode setting of UL 464.

Main Features

  • Bases enable quick and secure detector plug-in
  • SEMS screws provide easy wiring connection
  • Support for 12-24 AWG provides installation flexibility
  • Standby Current: 550 µA maximum VDC
  • SLC Operating Voltage: 15 to 32 VDC
  • SLC Standby Current: 300 µA maximum (base only, refer to applicable sensor specification)
  • High Volume Sound Output: Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone)
  • Low Volume Sound Output: Greater than 75 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone)
  • The detector used with this base must be tested and maintained regularly following NFPA 72 requirements.
  • The detector should be cleaned at least once a year.

General Information

Name: Fire-Lite B200S-LF-IV Intelligent Addressable Sounder Base, Low-Frequency, Ivory
Category: Fire-Lite Alarms by Honeywell, Fire, Fire Detection Devices, Detector Bases, ADI Pro Rewards
UPC Code:
Country of Origin: Mexico. Country of origin is subject to change.

Specifications